Show simple item record

dc.contributor.authorRokushika, Souji
dc.contributor.authorKihara, Kazuko
dc.contributor.authorYamamoto, Fumiko M.
dc.contributor.authorSubosa, Precilla F.
dc.date.accessioned2013-01-29T08:20:06Z
dc.date.available2013-01-29T08:20:06Z
dc.date.issued1991
dc.identifier.citationRokushika, S., Kihara, K., Yamamoto, F. M., & Subosa, P. F. (1991). Analysis of nitrite in aqueous solutions containing concentrated matrix ions using an octadecyl-poly(vinyl alcohol) gel microbore column and an electrochemical detector. Journal of High Resolution Chromatography, 14(1), 68–70.en
dc.identifier.issn1521-4168
dc.identifier.urihttp://hdl.handle.net/10862/1349
dc.description.abstractThe importance of the analysis of low level nitrite concentrations in aqueous samples is increasing in various fields such as environmental, food, and aquaculture chemistry. Recent progress in ion chromatography paved the way to the direct analysis of nitrite in water samples at ppm to sub ppb levels. However, analysis of low level nitrite in highly concentrated salt matrix still remains a difficult problem. The presence of a large amount of the matrix ion makes establishment of an ion exchange equilibrium very difficult in the column, often resulting in bad peak shapes [1]. In previous papers, we reported the analysis of a nitrite and other anions in chloride matrix on a conventional low capacity anion-exchange column by means of a heart-cut and recycling method [1] and by using a potassium chloride eluent [2]. To monitor the nitrite peak, both a UV detector and a conductimetric detector has been used [3]. Several groups have demonstrated the potential of an electrochemical detector for a specific and sensitive detection of nitrate. [4-6]. Poly(vinyl alcohol) (PVA) gel have been introduced recently as a chemically stable HPLC column packings [7-9]. It was found that when an acidic eluent was employed, a PVA gel and its acylated gel columns produced large capacity factors for nitrite [10].en
dc.language.isoenen
dc.publisherDr. Alfred Huethig Publishersen
dc.titleAnalysis of nitrite in aqueous solutions containing concentrated matrix ions using an octadecyl-poly(vinyl alcohol) gel microbore column and an electrochemical detectoren
dc.typeArticleen
dc.identifier.doi10.1002/jhrc.1240140118
dc.citation.volume14
dc.citation.issue1
dc.citation.spage68
dc.citation.epage70
dc.citation.journalTitleJournal of High Resolution Chromatographyen
seafdecaqd.library.callnumberVF SJ 0344
seafdecaqd.databank.controlnumber1991-14
dc.subject.asfachemical analysisen
dc.subject.asfanitritesen
dc.subject.asfawater analysisen
dc.subject.asfaanalytical techniquesen
dc.subject.asfachromatographyen


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Journal Articles [1229]
    These papers were contributed by Department staff to various national and international journals.

Show simple item record